NEC Bull NovaScale R620 User Manual page 269

Hide thumbs Also See for Bull NovaScale R620:
Table of Contents

Advertisement

On-screen error message
9064 Mixed CPU Steppings
detected
9038 Check date and time
settings (Chipset)
9001 Missing date and time
synchronization
9002 Memory not installed.
9003 Memory
implementation error
detected
9004 Real time clock error
(Chipset)
9005 Remote BMC access
failed
9006 HW Memory Test
failed.
9009 Chipset NMI occurred!
900A PEXA Link Width
Warning
900B PEXB Link Width
Warning
900D PEXD Link Width
Warning
900E PEXE Link Width
Warning
9021 Trace memory test
failed
902C BMCFW major revision
mismatched.
902D IPMB#1 SROM failure
detected
902E IPMB#2 SROM failure
detected.
902F PCI Device Test failed.
9060 Module#0 is not
present.
9061 Module#1 is not
present.
9039 Not keep last boot
order
9070 The error occurred
during water-cooling
unit sensor reading
NOTICE System is force
boot with POST
error
9000
9007
9008
9010 – 9015
NovaScale R620 User Guide
Cause
Different CPU steppings are
found.
Data and time settings are
incorrect.
Information delivery among
units failed
DIMM is not implemented.
DIMM is faulty.
Error is detected on memory
implementation.
RTC is faulty.
BMC of remote unit is faulty.
Memory is faulty.
BIOS NMI handler is executed
and POST is stopped.
PCI-EX Link is faulty.
Trace memory is faulty.
BMCFW revision does not
match.
IPMB#1 SROM is faulty.
IPMB#2 SROM is faulty.
PCI Device is faulty.
CPU/IO module#0 is not
mounted.
CPU/IO module#1 is not
mounted.
Unintended operations such
as incorrect DC off are
performed.
The sensor of water-cooling
kit is faulty.
Abnormality of one or both
sides of modules is detected.
A serious error occurred
during a POST.
Forced power off occurred by
another CPU/IO module has a
problem.
Cannot boot from target Disk.
Action
Check supported CPUs and replace the CPU. If
replacing the CPU does not help, replace CPU/IO
module.
If reconfiguring by using BIOS setup does not help,
replace the CPU/IO module.
Mount or replace the DIMM.
Check supported DIMMs and replace the DIMM. If
replacing the DIMM does not help, replace the
CPU/IO module.
Reconfigure RTC by using BIOS setup.
Check again if the CPU/IO module is mounted
properly. If this does not help, replace the CPU/IO
module.
Replace the DIMM. If replacing it does not help,
replace the CPU/IO module.
Obtain detailed information, and replace the CPU/IO
module.
Since performance becomes slightly lower, replace
the CPU/IO module in case of an emergency.
Replace the CPU/IO module.
Update SDR/PIA. If updating it does not help,
replace the CPU/IO module or ft Remote
Management Card (option).
If restarting does not help, replace the CPU/IO
module, ft Remote Management Card (option) or
centre plane.
Replace the CPU/IO module.
Mount the primary unit. If restarting does not help,
replace the CPU/IO module.
Mount the primary unit. If restarting does not help,
replace the CPU/IO module.
Reconfigure the boot option by using the BIOS
setup. If reconfiguring the boot option does not help,
replace the CPU/IO module.
Replace the water-cooling kit. If turning on/off AC
does not help, replace CPU/IO module or ft Remote
Management Card.
View other error information and the error
information of standby CPU/IO module.
There are some error messages in addition to this
error code.
Check the other error message.
Pull out another CPU/IO module and install it.
If this does not help, replace the CPU/IO module.
Check the target disk.
In addition, replace it if required.
If this does not help, replace the CPU/IO module.
7-7

Advertisement

Table of Contents

Troubleshooting