Directional Control Valve Options; 2-Position, 2-Way Manual Valve Used With Single-Acting Cylinder (Figure 1) - SPX Power Team PE55-E110 Series Operating Instructions Manual

Hydraulic pump
Table of Contents

Advertisement

DIRECTIONAL CONTROL VALVE OPTIONS

• Some valves return fluid to the reservoir when the pump stops or when the valve is shifted. The
correct valve must be used, especially when lifting a load.
• "Hold-to-run" controls are recommended and must be used with correct valves for certain applica-
tions, especially when lifting a load.
• Not all valves fit on all pumps.
When lifting or lowering a load, the load must be under operator control at all times and others must be
clear of the load. Use blocking and cribbing to guard against a falling load. Do not drop the load. The
use of a load lowering or metering valve is recommended in addition to the pump directional control
valve.

1. 2-Position, 2-Way Manual Valve Used With Single-acting Cylinder (Figure 1)

A.
To HOLD pressure, turn the valve control handle counterclockwise (CCW).
B.
Activate the pump unit to advance the cylinder.
C. When the cylinder has advanced to the desired position, deactivate the switch or remote switch, or turn
the pump unit OFF. The cylinder will HOLD pressure.
D. To retract the cylinder, turn the valve control handle clockwise (CW) slowly.
© 2014 SPX CORPORATION
NOTE
DANGER
Gauge
A
P
T
9584
PE55 SERIES (9584)
2-position, 2-way
Manual Valve
Port
Figure 1
10
Form No. 1000862