14 Inspection/maintenance

14 Inspection/maintenance
The equipment is subject to pressure!
▶ Risk of severe injury or death.
Depressurize the plant.
Completely drain the plant.
Hot plant components!
▶ Risk of burns.
Only work on plant that has cooled
down.
Servicing and maintenance work must only be performed
by trained personnel.
Do not extend hand lever. GEMÜ shall assume no liability
whatsoever for damages caused by improper handling or
third-party actions.
In case of doubt, contact GEMÜ prior to commissioning.
1. Use appropriate protective gear as specified in plant oper-
ator's guidelines.
2. Shut off plant or plant component.
3. Secure against recommissioning.
4. Depressurize the plant or plant component.
Ball valves are maintenance-free. No lubrication or routine
maintenance of the ball valve shaft is required. The shaft is
guided through a PTFE gland packing in the ball valve body.
The shaft seal is pretensioned and self-adjusting. However,
the operator must carry out regular visual examinations of the
ball valves, dependent on the operating conditions and the po-
tential danger in order to prevent leakage and damage.
If there is a leakage at the spindle nut, this can generally be
rectified by retightening the spindle nut. However, overtighten-
ing the spindle nut must be avoided.
Usually, retightening by between 30° and 60° will be sufficient
to rectify the leakage.
GEMÜ B22
WARNING
CAUTION
CAUTION
14.1 General information regarding hand lever
replacement
The following is required for hand lever replacement:
Allen key
1. Check the position of the ball indicated by the groove SZ
and compare with position indicator, rotate ball valve to
correct position if necessary.
ð Groove transverse to piping direction:
Ball valve closed.
ð Groove in piping direction:
Ball valve open.
▶ For flanged bodies, the hand lever is fitted offset by 90°.
14.1.1 Replacing the hand lever
14.1.1.1 Removing the hand lever
1. Remove the protective caps 30.
2. Unscrew the hexagon screws 32.
3. Do not lose the washers 31.
4. Unscrew the nut 24.
5. The hand lever 17 can be removed from the ball valve
body.
54 / 60
NOTICE
SZ
NOTICE
24
31
32
30
www.gemu-group.com
17