Inspection And Maintenance - GEM eSyStep 543 Operating Instructions Manual

Motorized angle seat globe valve
Table of Contents

Advertisement

14 Inspection and maintenance

WARNING
The equipment is subject to pressure!
▶ Risk of severe injury or death
Depressurize the plant.
Completely drain the plant.
CAUTION
Use of incorrect spare parts!
▶ Damage to the GEMÜ product
▶ Manufacturer liability and guarantee will be void
Use only genuine parts from GEMÜ.
CAUTION
Hot plant components!
▶ Risk of burns
Only work on plant that has cooled
down.
NOTICE
Exceptional maintenance work!
▶ Damage to the GEMÜ product
Any maintenance work and repairs not described in these
operating instructions must not be performed without
consulting the manufacturer first.
The operator must carry out regular visual examination of the
GEMÜ products dependent on the operating conditions and
the potential danger in order to prevent leakage and damage.
The product also must be disassembled and checked for
wear in the corresponding intervals.
1. Have servicing and maintenance work performed by
trained personnel.
2. Wear appropriate protective gear as specified in plant op-
erator's guidelines.
3. Shut off plant or plant component.
4. Secure the plant or plant component against recommis-
sioning.
5. Depressurize the plant or plant component.
6. Actuate GEMÜ products which are always in the same po-
sition four times a year.
7. If necessary, the end position counter User can be reset
after maintenance or other changes under parameter
Cycle Counter.
www.gemu-group.com
14.1 Spare parts
4
b
c
14
d
e
Item
Name
1
Valve body
4
Sealing washer
14
Shut-off seal
A
Actuator
a
Union nut
b
Spindle
c
Valve plug
d
Retaining washer
e
Nut
14.2 Removing the actuator
1. Move the actuator A to the open position.
2. Undo union nut a.
3. Lift actuator A off valve body 1.
4. Clean all parts of contamination (do not damage parts dur-
ing cleaning).
5. Check parts for potential damage, replace if necessary
(only use genuine parts from GEMÜ).
63 / 68
14 Inspection and maintenance
A
a
1
Order description
K550... (DN6 – DN15)
K514... (DN15 – DN50)
543...SVS...
9543...
-
-
-
-
-
GEMÜ 543 eSyStep
OPEN / CLOSE (Code AE)

Advertisement

Table of Contents
loading

Table of Contents