Victrix Tera V2 38 EU
80
1
70
60
50
Y1
40
30
20
10
0
0
Key (Fig. 37)
1
=
Head available to the system at speed 95% with by-pass closed
2
=
Head available to the system at speed 95% with by-pass open
3
=
Head available to the system at speed 65% with by-pass closed
4
=
Head available to the system at speed 65% with by-pass open
5
=
Circulator absorbed power at 95% speed with closed by-pass
6
=
Circulator absorbed power at 65% speed with closed by-pass

1.30 KITS AVAILABLE ON REQUEST

Check the complete list of kits available and which can be combined with the product, consult the Immergas website, the Im-
mergas Price List or the technical-commercial documentation (catalogues and data sheets).
48
2
3
6
200
400
600
5
4
800
1000
1200
Area between curves 1 and 3 = Available system head with bypass closed
Area between curves 2 and 4 = Available system head with bypass open
Area between curves 5 and 6 = Circulator absorbed power with bypass
closed
X1 =
Flow rate (l/h)
Y1 =
Head (kPa)
Y2 =
Power absorbed by pump (W)
80
70
60
50
40
30
20
10
0
1400
1600
1800
Y2