3.4

HYDRAULIC DIAGRAM

Key (Fig. 40):
1
- Gas valve
2
- D.H.W. flow switch
3
- Gas nozzle
4
- Flow limiter
5
- D.H.W. probe
6
- Condensate drain trap
7
- System filling cock
8
- D.H.W. heat exchanger
9
- System expansion vessel
10
- Positive (+) pressure point
11
- Pressure signal vent fitting
12
- Venturi
13
- Flow probe
14
- Ignition / detection electrode
15
- Air intake pipe
16
- Flue probe
17
- Flue sample point
18
- Air sample point
19
- Burner
20
- Return probe
21
- Fan
22
- Air vent valve
23
- Boiler circulating pump
24
- Absolute pressure switch
25
- 3-way valve (motorised)
26
- By-pass
27
- System draining cock
28
- 3 bar safety valve
29
- 3 bar safety valve drain fitting signal
30
- Air vent valve drain
G
- Gas supply
AC
- Domestic hot water outlet
AF
- Domestic hot water inlet
SC
- Condensate drain
M
- System flow
R
- System return
40