Immergas Victrix Tera V228 EU Manual page 56

Table of Contents

Advertisement

Error
Anomaly signalled
Code
Configuration error
15
Fan anomaly
16
20
Parasite flame block
Return probe
23
anomaly
Push button control
24
panel anomaly
Flue probe anomaly
29
Loss of remote control
31
communication
Low power supply
37
voltage
38
Loss of flame signal
Block due to loss of
43
flame signal
(1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised Service Centre)
(2) The anomaly can only be verified in the list of errors in the "Information" menu
56
Cause
If the board detects an anomaly or incongruity on the elec-
tric wiring, the boiler will not start.
This occurs if the fan has a mechanical or electrical fault.
This occurs in the event of a leak on the detection circuit or
anomaly in the flame control unit.
The board detects an anomaly on the return NTC probe
The board detects an anomaly on the pushbutton panel.
The board detects an anomaly on the flue probe.
This occurs if an incompatible remote control is connected,
or if communication between the boiler and the remote
control is lost.
This occurs when the power supply voltage is lower than the
allowed limits for the correct boiler operation.
This occurs when the boiler is ignited correctly and the
burner flame switches off unexpectedly; a new attempt at
ignition is performed and if normal conditions are re-
stored, the boiler does not have to be reset.
This occurs if the ''Flame signal loss'' error occurs many
times in a row within a preset period (38).
Boiler status / Solution
If normal conditions are restored the
boiler restarts without having to be
reset. Check that the boiler is config-
ured correctly (1)
Press the Reset button (1)
Press the Reset button (1)
The boiler does not start (1)
If normal conditions are restored the
boiler restarts without having to be
reset (1).
The boiler does not start (1)
Disconnect and reconnect the power
to the boiler. If the remote control is
still not detected on re-starting, the
boiler will switch to local operating
mode, i.e. using the controls on the
control panel. In this case, the
"Central Heating" (1) function cannot
be activated.
If normal conditions are restored the
boiler restarts without having to be
reset (1)
If normal conditions are restored the
boiler restarts without having to be
reset (1) (2)
Press the Reset button, before
restarting, the boiler will run a
post-ventilation cycle. (1)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Victrix tera v232 euVictrix tera v238 eu

Table of Contents