Immergas Victrix Tera V228 EU Manual page 73

Table of Contents

Advertisement

Id
Parameter
Parameter
Max DHW
P0
output
P1
Min CH output
P2
Max CH output
P3
-
Pump function-
P4
ing
External probe
P5
correction
P6
-
P7
Remote control
P8
-
Description
Defines the maximum heat output percentage of the boiler
during the D.H.W. phase compared to the maximum heat
output available
Defines the minimum output percentage of the boiler in cen-
tral heating mode
Defines the maximum heat output percentage of the boiler
during the central heating mode compared to the maximum
heat output available
Not available for this model
The pump can function in two ways.
0 intermittent: in winter "mode" the circulator is managed
by the room thermostat or by the remote control.
1 continuous: in "winter" mode the circulator is always
powered and is therefore always in operation.
If the reading of the external probe is not correct it is possible
to correct it in order to compensate any environmental
factors.
Not available for this model
Sets the dialogue protocol with the remote device
0: IMG BUS. Select this mode when connecting an Immer-
gas remote control (e.g. CARv2) to terminals 44-41
1: Not available on this model
2: Select this mode when a commercial remote control is
connected to terminals 44-41 (with this selection, the
control of the domestic hot water adjustments and max set
central heating flow remains available on the boiler panel)
Not available for this model
Range
Default
0 - 100 %
100 %
0 - P2
0 %
VICTRIX
TERA V2 28
EU
G20 = 83
G31 = 83
VICTRIX
TERA V2 32
EU
0 - 100 %
G20 = 86
G31 = 86
VICTRIX
TERA V2 38
EU
G20 = 86
G31 = 86
-
-
0 - 1
0
-9 ÷ 9 K
0
-
-
0 - 2
0
-
-
Customised
value
73