Immergas Victrix Tera V228 EU Manual page 36

Table of Contents

Advertisement

Installation clearances (Fig. 26)
The minimum installation clearance measurements of the Ø
80/80 separator terminal kit have been stated in some limit condi-
tions.
Extensions for separator kit Ø 80/80
The maximum vertical straight length (without bends) that can be used for Ø 80 intake and exhaust pipes is 35 metres, regardless from
whether they are used for intake or exhaust.
The maximum horizontal straight length (with bend in suction and in exhaust) that can be used for Ø 80 intake and exhaust pipes is 30
metres, regardless from whether they are used for intake or exhaust.
Please note the type of installation C
To aid in the removal of possible condensate forming in the exhaust pipe, tilt the pipes towards the appliance with a minimum
slope of 5% (Fig. 27).
C
36
must be done with a natural draught flue.
43
S
L
C
A
Key (Fig. 27):
83
A
- Intake
C
- Minimum slope 5%
S
- Exhaust
27
C
43
26

Advertisement

Table of Contents
loading

This manual is also suitable for:

Victrix tera v232 euVictrix tera v238 eu

Table of Contents