Victrix Tera V2 38 EU
1. Remove old seals.
2. Install the cord packing (8) by putting the two ends together and pressing them into the housing. Press the gasket back onto the areas
identified at '9 o'clock' (A), '12 o'clock' (B) and '3 o'clock' (C) with respect to the ends and then lay the rest of the gasket inside the hous-
ing.
3. Install the gasket (9) by aligning it as shown in Fig. 65 and pressing it into the housing.