Immergas Victrix Tera V228 EU Manual page 86

Table of Contents

Advertisement

Victrix Tera V2 38 EU
1. To access the inside of the appliance, remove the casing as indicated in Paragr. 3.22.
2. Unscrew the 4 manifold fastening nuts (1, Fig. 67) and gently pull them out orthogonally towards yourself.
3. Unscrew the fixing screws (6) of the ignition and detection electrode (5) and remove it.
4. Insert the tip of a flat-blade screwdriver (10) into the groove (12) of the 3 clips (2) of the insulating fastener. Lever the retaining tongue
(2) out of its seat (11) and pull it out.
5. Replace the insulating panel (1) and secure it with the 3 clips (2) which were previously removed: insert them under the relevant
screws (7) and push them until the retaining tab (2) snaps into its seat (11) on the manifold.
6. Check the condition of the gaskets (8) and (9) and replace them if necessary after removing them from their seats as described in Par-
agraph 3.24.
7. Refit the ignition and detection electrode (5) using the previously removed screws (6) and replace the relative gasket (4).
Electrode distance
To regain optimal operation, make sure that the following variables are respected when refitting the electrodes.
86
2
10
8
9
11
9
1
5.5±1
12
2
2
8
1
2
7
5
4
3
2
6
62
63

Advertisement