Solar function
This function is activated automatically id the boiler detects a probe on the DHW inlet (optional) or if the "Solar ignition delay" parame-
ter is more than 0 seconds.
During a withdrawal, if the inlet water is hot enough or if there is "Solar ignition delay" time, the boiler does not switch on, the D.H.W.
withdrawal symbol (
) appears on the display along with the flashing solar function symbol (
When the water supplied by the solar system is at a temperature lower than what is set, and if the "Solar ignition delay" time has elapsed,
the boiler switches on. At this point, the solar function symbol remains permanently on.
Operation with optional external probe
In the case of a system with an external probe, the boiler flow temperature for central heating is managed by the external probe depending
on the external temperature measured (Par. 1.11). The flow temperature can be modified by selecting the functioning curve via the but-
tons (or on the CAR
control panel, if connected to the boiler) selecting a value from "0 to 9".
V2
With external probe present, the relative symbol
In the central heating mode, if the temperature of the water contained in the system is sufficient to heat the radiators, the boiler can only
function with the activation of the pump.
"Stand-by" Mode
Press button "
" repeatedly until the symbol (
anti-block and 3-way function and signalling of any anomalies are guaranteed.
OFF mode
In "Stand-by" and "Off" mode, the appliance is to be considered still live. In "Off" mode, a lit
"dot" is displayed in the centre of the display.
Display operation
The display lights up while the control panel is being used; after a set inactivity period, the brightness drops until only the active symbols
are displayed. The lighting mode can be varied via parameter "t8" in the P.C.B. programming menu.
54
(optional).
will appear on the display. (Fig. 39).
) appears. The boiler remains off from this moment, though the antifreeze, pump
).