Download Print this page

Features; Display And Indicators; Buttons - Banner Q5X Instruction Manual

Dual discrete outputs and iolink
Hide thumbs Also See for Q5X:

Advertisement

 

Features

The Q5X Laser Measurement Sensor has three major features. 
Q5X Features
2
1

Display and Indicators

The display is a 4­digit, 7­segment LED. Run mode is the primary view displayed. 
For 2-pt, BGS, FGS, and DYN TEACH modes, the display shows the current distance to the target in centimeters. For Dual
TEACH mode, the display shows the percentage matched to the taught reference surface. A display value of 999P indicates 
the sensor has not been taught. 
Display in Run Mode 
1
STB DYN FGS BGS
Output Indicator
On: The output is on
Off: The output is off
Stability Indicator (STB)
On—Stable signal within the specified sensing range
Flashing—Marginal signal (low excess gain), the target is out­
side the limits of the specified sensing range, or a multiple
peak condition exists
Off—No target is detected within the specified sensing range
Buttons 
Use the sensor buttons (SELECT)(TEACH), (+)(CH1/CH2), and (-)(MODE) to program the sensor. 
(SELECT/TEACH)
Press to select menu items in Setup mode
July 25, 2023
Q5X With Dual Discrete Outputs And IO-Link Instruction Manual
3
1.
Two output indicators (amber) 
2.
Display 
3.
Buttons 
1.
Stability Indicator (STB—Green) 
2
2.
Active TEACH Indicators
DYN—Dynamic (Amber) 
FGS—Foreground Suppression (Amber) 
BGS—Background Suppression (Amber) 
Button Layout
© Banner Engineering Corp.
Active TEACH Indicators (DYN, FGS, and BGS)
DYN, FGS, and BGS all off—Two­point TEACH mode select­
ed (default)
DYN on—Dynamic TEACH mode selected
FGS on—Foreground suppression TEACH mode selected
BGS on—Background suppression TEACH mode selected
DYN, FGS, and BGS all on—Dual TEACH mode selected
 