Download Print this page

Mount The Device; Wiring Diagram - Banner Q5X Instruction Manual

Dual discrete outputs and iolink
Hide thumbs Also See for Q5X:

Advertisement

Q5X With Dual Discrete Outputs And IO-Link Instruction Manual
Orientation for a color or luster difference
(Optimal)
Horizontal
Orientation

Mount the Device

1.
If a bracket is needed, mount the device onto the bracket. 
2.
Mount the device (or the device and the bracket) to the machine or equipment at the desired location. Do not tighten
the mounting screws at this time. 
3.
Check the device alignment. 
4.
Tighten the mounting screws to secure the device (or the device and the bracket) in the aligned position. 

Wiring Diagram

Channel 2 as PNP Discrete or PFM Output 
NOTE: Open lead wires must be connected to a terminal block. 
NOTE: The Channel 2 wire function and polarity is user­selectable. The default for the wire is PNP out­
put.  
 
(1)
Applying tilt to sensor may improve performance on reflective targets. The direction and magnitude of the tilt depends on the application, but a 15° tilt is often
sufficient.
 
10
Orientation for highly reflective target
Orientation
bn (1)
+
10-30 V DC
bk (4)
CH1
Load
bu (3)
wh (2)
CH2
Load
Continued from page 9
(1)
Reflective
Surface
(optional)
Channel 2 as Remote Input 
bn (1)
CH1
bk (4)
Load
bu (3)
CH2
wh (2)
Remote Input
© Banner Engineering Corp.
 
+
2
10-30 V DC
3
July 25, 2023
 
1
4
 

Advertisement

loading