Example Application Under Windows - Peak PCAN-USB Pro FD User Manual

Table of Contents

Advertisement

This example shows a connection between the PCAN Interface and a control unit
(ECU). The upper example shows a connection with a cable which is terminated
with 120 Ω at both ends. At the lower example the connection is made with
termination adapters.
3.5.3 Maximum Bus Length
The maximum bus length depends primarily on the bit rate:
Nominal bit rate Buslength
1 Mbit/s
500 kbit/s
250 kbit/s
125 kbit/s
50 kbit/s
25 kbit/s
The listed values have been calculated on the basis of an idealized system and can
differ from reality.
Note: For CAN FD, the same maximum bus lengths applys as for CAN,
despite the higher data bit rate of CAN FD. The dependency is based
on the bit rate during the arbitration, called nominal bit rate.

3.6 Example Application under Windows

As an example application for accessing the interface, run the CAN monitor
PCAN-View and/or the LIN monitor PLIN-View Pro from the Windows Start menu.
3   Installation
PCAN-USB Pro FD
User Manual 2.0.0
© 2023 PEAK-System Technik GmbH
40 m
110 m
240 m
500 m
1.3 km
2.5 km