Can Cabling - Peak PCAN-USB Pro FD User Manual

Table of Contents

Advertisement

Pin
Assignment
1
CAN_V+ (external, optional)
2
CAN_Low
3
CAN_GND
4
LIN
5
LIN_GND
6
LIN_GND
7
CAN_High
8
Not assigned
9
LIN_V
Bat
PEAK System offers a pre-configured LIN connection cable
(IPEK-003013), wich allows the tapping of individual lines. The LIN and
the supply lines are lead directly out to separate plugs and the CAN
lines are forwarded to a D-Sub plug.

3.5 CAN Cabling

3.5.1 Termination
The High-speed CAN bus (ISO 11898-2) must be terminated with 120 Ω on both
ends. The termination prevents interfering signal reflections and ensures the
proper operation of the transceivers of the connected CAN nodes (CAN interfaces,
control devices).
3.5.2 Example of a Connection
3   Installation
PCAN-USB Pro FD
User Manual 2.0.0
© 2023 PEAK-System Technik GmbH
D-Sub socket
17