1.1
Properties at a Glance
Common
Interface for High-speed USB 2.0 (compatible to USB 1.1 and USB 3.0)
■
Transmitting and receiving of CAN FD and LIN messages using 2 D-Sub
■
connections (both with pin assignment for the CAN FD and LIN bus)
Time stamp resolution 1 µs
■
5-Volt supply at the D-Sub connector can be activated through a solder jumper,
■
e.g., for external bus converter
Voltage supply via USB
■
Extended operating temperature range from -40 to +85 °C (-40 to +185 °F)
■
CAN
Complies with CAN specifications 2.0 A/B and FD
■
CAN FD support for ISO and Non-ISO standards switchable
■
CAN FD bit rates for the data field (64 bytes max.) from 25 kbit/s up to 12 Mbit/s
■
CAN bit rates from 25 kbit/s up to 1 Mbit/s
■
FPGA implementation of the CAN FD controller
■
NXP TJA1044GT CAN transceiver
■
Each CAN FD channel is separately opto-decoupled against USB and LIN
■
up to 500 V
CAN termination can be activated through solder jumpers, separately for each
■
CAN channel
Measurement of bus load including error frames and overload frames on the
■
physical bus
Induced error generation for incoming and outgoing CAN messages
■
1 Introduction
PCAN-USB Pro FD
User Manual 2.0.0
© 2023 PEAK-System Technik GmbH
6