Download Print this page

Mitsubishi Electric FR-700PJ Manual page 61

Advertisement

Name (model)
High power factor
converter

FR-HC2-(H)
K
(FR-HCB2)
(FR-HCL21)
(FR-HCL22) FR-HC2
Accessory
63
 Substantially suppresses power harmonics to realize the equivalent
capacity conversion coefficient K5 = 0 in "the Harmonic Suppression
Guidelines for Consumers Who Receive High Voltage or Special High
Voltage" in Japan.
 Specification
200V
Model FR-HC2
(*2)
7.5K
15K
30K
Applicable inverter
3.7K to
7.5K to
15K to
capacity (*1)
7.5K
15K
30K
Rated input
Three-phase 200V to 220V 50Hz
voltage/frequency
200V to 230V 60Hz
Rated input
33
61
115
current (A)

The total capacity of the connected inverters.

If a high power factor converter (FR-HC2) is purchased, it comes with reactor 1 (FR-HCL21), reactor 2 (FR-HCL22), and an outside box (FR-
HCB2).
(If an H280K or higher is purchased, it comes with FR-HCL21, FR-HCL22, FR-HCC2, FR-HCR2, and FR-HCM2.)
 Outline dimension
High power factor
converter FR-HC2
Voltage Capacity
W
H
7.5K
220
260
15K
250
400
200V
30K
325
550
55K
370
620
75K
465
620
H7.5K
220
300
H15K
220
300
H30K
325
550
H55K
370
670
H75K
325
620
400V
H110K
465
620
H160K
498
1010
H220K
498
1010
H280K
680
1010
H400K
790
1330
H560K
790
1330
High power factor converter
Outside box
P.CPY PWR
REGEN
.......
DRIVE
FA
PSCLR
W
D
W
Specification and Structure
 The power regeneration function comes standard.
 The common converter driving with several inverters is possible.
55K
75K
H7.5K H15K H30K H55K H75K H110K H160K H220K H280K H400K H560K
30K to
37K to
3.7K to
7.5K to
15K to
30K to
55K
75K
7.5K
15K
30K
55K
Three-phase 380V to 460V 50/60Hz
215
278
17
31
57
110
Reactor 1 FR-HCL21 (1)
Reactor 2 FR-HCL22 (1)
D
W
H
D
170
132
150
100
237.5
190
162
172
126
257.5
195
195
210
150
342.5
250
210
180
200.5
432.5
300
240
215
215.5
190
132
140
100
237.5
190
162
170
126
257.5
195
182
195
101
342.5
250
282.5
245
165
392.5
250
210
175
210.5
300
240
230
220
380
280
295
274.5
380
330
335
289.5
380
330
335
321
440
402
460
550
440
452
545
645
Reactor 1, Reactor 2
W
D
400V
37K to
55K to
90K to
110K to
160K to
75K
110K
160K
220K
280K
139
203
290
397
506
Outside box FR-HCB2
W
H
D
W
230
140
190
260
165
305
180
270
380
280
474
460
280
400
220
140
260
165
190
300
180
365
200
270
430
395
280
300
500
440
370
350
560
520
430
400
620
620
480
690
700
560
632
675
705
632
720
745

Install reactors (FR-HCL21 and 22) on a
horizontal surface.

FR-HCB2 is not provided for H280K or higher. A
filter capacitor and inrush current limit resistors
D
are provided instead.
200K to
280K to
400K
560K
716
993
(Unit mm)
(2)
H
D
320
165
450
203
450
250
320
165
450
203
350
250
450
380
450
440