Download Print this page

Mitsubishi Electric FR-700PJ Manual page 22

Advertisement

Func-
Parameter
tion
41
Up-to-frequency sensitivity
42
Output frequency detection
Output frequency detection for reverse
43
rotation
44
Second acceleration/deceleration time
45
Second deceleration time
46
Second torque boost
47
Second V/F (base frequency)
Second stall prevention operation
48
current
51
Second electronic thermal O/L relay
52
DU/PU main display data selection
54
FM terminal function selection
55
Frequency monitoring reference
56
Current monitoring reference
57
Restart coasting time
58
Restart cushion time
59
Remote function selection
60
Energy saving control selection
65
Retry selection
Stall prevention operation reduction
66
starting frequency
67
Number of retries at fault occurrence
68
Retry waiting time
69
Retry count display erase
70
Special regenerative brake duty
71
Applied motor
72
PWM frequency selection
73
Analog input selection
74
Input filter time constant
Reset selection/disconnected PU
75
detection/PU stop selection
77
Parameter write selection
78
Reverse rotation prevention selection
 79
Operation mode selection
80
Motor capacity
82
Motor excitation current
83
Rated motor voltage
84
Rated motor frequency
90
Motor constant (R1)
96
Auto tuning setting/status
117
PU communication station number
118
PU communication speed
119
PU communication stop bit length
120
PU communication parity check
121
Number of PU communication retries
122
PU communication check time interval
123
PU communication waiting time setting
124
PU communication CR/LF selection
Terminal 2 frequency setting gain
 125
frequency
Terminal 4 frequency setting gain
126
frequency
Name
Setting Range
0 to 100%
0 to 400Hz
0 to 400Hz, 9999
0 to 3600s
0 to 3600s, 9999
0 to 30%, 9999
0 to 400Hz, 9999
0 to 150%, 9999
0 to 500A, 9999
0, 5, 8 to 12, 14, 20,
23 to 25, 50 to 55, 61,
62, 64, 100
1 to 3, 5, 8 to 12, 14, 21,
24, 50, 52, 53, 61, 62
0 to 400Hz
0 to 500A
0, 0.1 to 5s, 9999
0 to 60s
0 to 3
0, 9
0 to 5
0 to 400Hz
0 to 10, 101 to 110
0.1 to 600s
0
0 to 30%
0, 1, 3, 13, 23, 40, 43,
50, 53, 120, 210
0 to 15
0, 1, 10, 11
0 to 8
0 to 3, 14 to 17
0 to 2
0 to 2
0 to 4, 6, 7
0.4 to 15kW, 9999
0 to 500A, 9999
0 to 1000V
10 to 120Hz
0 to 50, 9999
0, 11, 21
0 to 31 (0 to 247)
48, 96, 192, 384
0, 1, 10, 11
0 to 2
0 to 10, 9999
0, 0.1 to 999.8s, 9999
0 to 150ms, 9999
0 to 2
0 to 400Hz
0 to 400Hz
Minimum
Refer
Initial
Setting
Value
Increments
Page
0.1%
10%
0.01Hz
6Hz
0.01Hz
9999
0.1s
5/15s

0.1s
9999
0.1%
9999
0.01Hz
9999
0.1%
9999
0.01A
9999
1
0
1
1
0.01Hz
60Hz
Rated
0.01A
inverter
current
0.1s
9999
0.1s
1s
1
0
1
0
1
0
0.01Hz
60Hz
1
0
0.1s
1s
1
0
0.1%
0%
1
0
1
1
1
1
1
1
1
14
1
0
1
0
1
0
0.01kW
9999
0.01A
9999
200V/400V
0.1V

0.01Hz
60Hz
0.001
9999
1
0
1
0
1
192
1
1
1
2
1
1
0.1s
0
1
9999
1
1
0.01Hz
60Hz
0.01Hz
60Hz
Customer
to
Setting
34
34
34
31
31
30
30
33
31
35
35
35
35
36
36
37
37
38
33
38
38
38
33
38,41
39
39
39
40
40
40
40
41
42
42
42
42
42
42
42
42
42
42
42
42
42
43
43
24

Advertisement

loading