Parameter
Name
Number
Pr.CL
Parameter clear
ALLC
All parameter clear
Er.CL
Faults history clear
Pr.CH
Initial value change list
IPM parameter
IPM
initialization
Automatic parameter
AUTO
setting
Initial
Unit
Range
Value
1
0
0, 1
1
0
0, 1
1
0
0, 1
1
0
0, 1, 12
Application
Setting "1" returns all parameters except
calibration parameters to the initial values.
Setting "1" returns all parameters to the initial
values.
Setting "1" clears eight past faults.
Displays and sets the parameters changed
from the initial value.
Use this parameter to select the IPM motor
control and to change parameter settings to
the settings required to drive an IPM motor.
Parameter settings are changed as a batch.
Those include communication parameter
settings for the Mitsubishi's human machine
interface (GOT) connection and the
parameter setting for the rated frequency
settings of 50Hz.
Refer
to
page
53
53
53
53
77
53
22