Remote Command Responses; Io Line Monitoring - Digi XBee ZNet 2.5 Product Manual

Oem rf modules
Table of Contents

Advertisement

Remote command responses

If the remote device receives a remote command request transmission, and the API frame ID is non-
zero, the remote will send a remote command response transmission back to the device that sent the
remote command. When a remote command response transmission is received, a device sends a
remote command response API frame out its UART. The remote command response indicates the
status of the command (success, or reason for failure), and in the case of a command query, it will
include the register value.
The device that sends a remote command will not receive a remote command response frame if:
The destination device could not be reached
The frame ID in the remote command request is set to 0.

IO line monitoring

XBee ZNet 2.5 modules support analog inputs and digital IO. Analog and digital IO can be set or read.
The XBee ZNet 2.5 supports the following IO functions:
Table 9:
Module Pin Names
CD/DIO12
PWM0/RSSIM/DIO10 6
PWM/DIO11
SLEEP_RQ/DIO8
DIO4
CTS/DIO7
ON_SLEEP/DIO9
Table 10:
Module Pin Names
ASSOC/DIO5
RTS/DIO6
AD3/DIO3
AD2/DIO2
AD1/DIO1
AD0/DIO0
Setting the configuration command that corresponds to a particular pin will configure the pin. IO line
command settings include the following:
XBee ZNet 2.5 / XBee PRO Znet 2.5 OEM RF Modules Product Manual
Module Pin Numbers
4
7
9
11
12
13
Module Pin Numbers
15
16
17
18
19
20
Configuration Command
P2
P0
P1
IO Configuration not supported
D4
D7
IO Configuration not supported
Configuration Command
D5
D6
D3
D2
DI
D0
IO line monitoring
47

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xbee pro znet 2.5

Table of Contents