Unigas G258A Manual Of Installation - Use - Maintenance page 204

Microprocessor controlled gas burners
Hide thumbs Also See for G258A:
Table of Contents

Advertisement

ConF > binF
This setting decides on the use of the binary inputsD1, D2, DG
b
Parameter
bin1
binary imput
terminals
1 (
DG
– D1)
bin2
binary imput
terminals
2 (
к
DG – D2)
(bold = factory settings)
ConF > dISP
.Both displays can be customized to suit your needs by configuring the displayed value, decimal, time out and blocking
Parameter
diSU
pper display (red)
diSL
lower display (green)
tout
timeout
dECP
decimal point
CodE
level lockout
(bold = factory settings)
Value
0
1
2
3
4
Value
0
1
2
3
4
6
7
0
1
2
3
4
6
7
0..180..250
0
1
2
0
1
2
3
Description
without function
0 =
set-point changeover
1 =
(SP1 / SP2)
set-point shift (Opr > dSP parameter = value of set-point modify)
2 = l
input alarm
3 =
changeover of operating mode
open = modulating operation
DG-D2
close = 2 stage operation
DG-D2
Description
Display value for upper display
display power-off
0 =
analog input 1 (InP1) value
1 =
analog input 2 (InP2) value
2 =
analog input 3 (InP3) value
3 =
controller's angular positioning
4 =
set-point value
6 =
в
end value with thermal shock protection
7 =
Display value for lower display
display power-off
0 =
analog input 2 (InP2) value
1 =
analog input 2 (InP2) value
2 =
analog input 2 (InP2) value
3 =
controller's angular positioning
4 =
set-point value
6 =
в
end value with thermal shock protection
7 =
time (s) on completion of which the controller returns automatically to the
basic display, if no button is pressed
no decimal place
0 =
one decimal place
1 =
two decimal place
2 =
no lockout
0 =
configuration level lockout
1 =
parameter and configuration level lockout
2 =
keyboard lockout
3 =
11
:
З:
(ConF)
(PArA & ConF)

Advertisement

Table of Contents
loading