Unigas G258A Manual Of Installation - Use - Maintenance page 125

Microprocessor controlled gas burners
Hide thumbs Also See for G258A:
Table of Contents

Advertisement

InP
sp. r
0
Def. remote setpoint
typ.
30
Probe type, signal, enable custom linearization,
Type
Probe type
Sensore:
0
TC J °C
1
TC J °F
2
TC K °C
3
TC K °F
4
TC R °C
5
TC R °F
6
TC S °C
7
TC S ° F
8
TC T °C
9
TC T °F
28
29
30
PT100 °C
31
PT100 °F
32
JPT100 °C
33
JPT100 °F
34
PTC °C
35
PTC °F
36
NTC °C
37
NTC °F
38
0...60 mV
39
0...60 mV
40
12...60 mV
41
12...60 mV
42
0...20 mA
43
0...20 mA
44
4...20 mA
45
4...20 mA
46
0...10 V
47
0...10 V
48
2...10 V
49
2...10 V
50
0...5 V
51
0...5 V
52
1...5 V
53
1...5 V
54
0...1 V
55
0...1 V
56
200mv..1V
57
200mv..1V
58
Cust10 V-20mA
59
Cust10 V-20mA
60
Cust 60mV
61
Cust 60mV
62
PT100-JPT
63
64
For custom linearization:
- LO signal is generated with variable below Lo.S or at minimum calibration
value
- HI signal is generated with variable above Lo.S or at maximum calibration
value
80379_MHW_600V-T73_06-2012_ENG
• InP
Input settings
0 default (remote setpoint present)
+2 Times of pre-heating and gradients of set digit/sec
and main input scale
without decimal point
with decimal point
TC
0/1000
0.0/999.9
32/1832
32.0/999.9
0/1300
0.0/999.9
32/2372
32.0/999.9
0/1750
0.0/999.9
32/3182
32.0/999.9
0/1750
0.0/999.9
32/3182
32.0/999.9
-200/400
-199.9/400.0
-328/752
-199.9/752.0
TC
CUSTOM
CUSTOM
TC
CUSTOM
CUSTOM
-200/850
-199.9/850.0
-328/156 2
-199.9/999.9
-200/600
-199.9/600.0
-328/1112
-199.9/999.9
-55/120
-55.0/120.0
-67/248
-67.0/248.0
-10/70
-10.0/70.0
14/158
14.0/158.0
-1999/9999
-199.9/999.9
Custom scale
Custom scale
-1999/9999
-199.9/999.9
Custom scale
Custom scale
-1999/9999
-199.9/999.9
Custom scale
Custom scale
-1999/9999
-199.9/999.9
Custom scale
Custom scale
-1999/9999
-199.9/999.9
Custom scale
Custom scale
-1999/9999
-199.9/999.9
Custom scale
Custom scale
-1999/9999
-199.9/999.9
Custom scale
Custom scale
-1999/9999
-199.9/999.9
Custom scale
Custom scale
-1999/9999
-199.9/999.9
Custom scale
Custom scale
-1999/9999
-199.9/999.9
Custom scale
Custom scale
-1999/9999
-199.9/999.9
Custom scale
Custom scale
-1999/9999
-199.9/999.9
Custom scale
Custom scale
CUSTOM
CUSTOM
PTC
CUSTOM
CUSTOM
NTC
CUSTOM
CUSTOM
S, R range 0...1750°C; error < 0.2% f.s. (t > 300°C) / for other
T
B
U
Max. non-linearity error for
thermocouples (TC),
resistors (PT100) and
G
thermistors (PTC, NTC).
D
C
The error is calculated as
deviation from theoretical
value and is expressed as
percentage of full scale
NTC error < 0.5% f.s.
(in °C).
Tc: J, K, E, N, L
JPT100 and PTC
PT100 scale -200...850°C
flt
0.1
(if = 0 excludes averaging filter on
fld
0.5
Digital filter on input
dp. s
1
Decimal point position for
Minimum limit of main
lo. s
0.0
850.0
Maximum limit of main
xi. s
0
Offset correction
ofs.
of main input
Lower limit for setting SP
lo. l
30.0
and absolute alarms
Upper limit for setting SP
xi. l
130.0
and absolute alarms
range; error < 0.5% f.s.
error < 0.2% f.s. (t > -150°C)
range 44...1800°C; error < 0.5% f.s. (t > 300°C) / range
44,0...999,9; error < 1% f.s. (t > 300°C)
range -99,9...99,9 and -99...99°C; error < 0.5% f.s. / for other
range; error < 0.2% f.s. (t > -150°C)
error < 0.2% f.s. (t > 300°C)
error < 0.2% f.s. (t > 200°C)
range 0...2300; error < 0.2% f.s. / for other range;
error < 0.5% f.s.
error < 0,2% f.s.
error < 0,2% f.s.
Precision better than 0,2% f.s. at 25°C
In range 0...50°C:
• Precision better than 0,2% f.s. in range -200...400°C
• Precision better than 0,4% f.s. in range +400...850°C
(where f.s. refers to range -200... +850°C)
Digital filter on input
0.0 ... 20.0 sec
sample value)
0 ... 9.9
display
scale points
dP_S
Format
0
xxxx
1
xxx.x
input scale
2
xx.xx (*)
3
x.xxx (*)
(*) not available for TC, RTD,
PTC and NTC scales
min...max input range
input scale
selected in tyP
min...max input range
input scale
selected in tyP
-999 ... 999
scale points
Lo.S ... Hi.S
Lo.S ... Hi.S
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

G335aG380aG400a