Removal Procedure; Removal Procedure Of Indoor Unit - Gree Dettson LOMO 19 Installation Manual

Single zone ductless heat pump
Table of Contents

Advertisement

11. Removal Procedure

11.1 Removal Procedure of Indoor Unit

Step
Before disassemble
Turn off the air conditioner and disconnect the power
before disassemble the air conditioner.
1. Remove filter
Hold the handle on the filter, pull it upwards to let the
clasp at the top part of the filter loose, push it forwards
and then the filter can be pulled out.
2. Remove guide louver
Push out the plug pin on guide louver, bend the guide
louver with hand and then separate the guide louver
from the crank shaft of step motor to remove it.