Gree Dettson LOMO 19 Installation Manual page 101

Single zone ductless heat pump
Table of Contents

Advertisement

Step
8. Remove motor and cross flow fan
Remove 3 screws fixing motor clamp and then remove
a
the motor clamp.
Remove 2 screws fixing motor fixed clip and then
b
remove motor fixed clip, cross flow fan and motor.
9. Remove swing motor
Screw off the screw that are locking the swing motor
and take the motor off.
98
Procedure
Cross flow fan
Service Manual
Screws
Motor fixed clip
Screws
Motor
Screw
Installation and Maintenance

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents