Gree Dettson LOMO 19 Installation Manual page 112

Single zone ductless heat pump
Table of Contents

Advertisement

Service Manual
Step
7. Remove electric box assy
Remove the terminals, lift up and rotate the electrical
box assy to the right so that the snaps on the clapboard
are removed and the electrical box assy are removed.
8. Remove motor and motor support
Remove the screws fixing the motor and then remove
the motor.
Remove the screws fixing the motor support and lift the
motor support to remove it.
9. Remove clapboard assy
Remove the screws fixing the clapboard assy and then
remove the clapboard assy.
Installation and Maintenance
Procedure
Motor support
Motor
Electric box assy
Clapboard assy
109

Hide quick links:

Advertisement

Table of Contents
loading