Local codes may require a disconnect switch within sight of the indoor unit. For these
installations, use a DFS Disconnect Switch Accessory Kit (Part No: DFS-SWITCH-A) to break
wires going to the N(1), 2, 3 terminals on the indoor unit, as shown in the wiring diagram below:
Interconnecting Cable with Disconnect Switch Wiring Diagram
CONDENSATE REMAOVAL
Install condensate drain to safely and effectively route condensate water to a safe location. Use a flexible
condensate drain hose to fit over the factory 5/8-inch (16mm) drainage port. The high wall indoor units
have an internal condensate trap. Adding an external trap is not required.
All condensate drains must meet local codes and regulations. If adequate gravity drainage cannot be
provided, a field-installed condensate pump must be used. Refer to manufacturer's installation
instructions, specifications and operating details supplied with condensate pump.