Split system single phase type
Programming lock (27):
If the programming lock is activated, the setting
values are displayed but may no longer be changed.
Temporary Suspension of Programming
The
programming
deactivated at programming level. To do this,
simultaneously press the OK and ESC keys for at
least 3 seconds. The temporary suspension of the
programming lock remains in effect until you exit the
programming.
Heating Circuit Assignment
LINE NO.
70
Software version
The indication shows the current version of the user
interface.
4.3.3 Time Program Functions (heating circuit 1 & 2, DHW, cooling)
Several control programs are available for the heating
circuits and the production of DHW. They are initiated
in "Automatic" mode and control the change in
temperature levels (and therefore the associated
setpoints, reduced and comfort) via the adjusted
changeover times.
Changeover Points
Line no.
HC1
HC2
4/DHW
500
520
560
501
521
561
502
522
562
503
523
563
504
524
564
505
525
565
506
526
566
Standard Program
Line no.
516, 536, 576, 616
All time programs can be reset to factory settings.
Each time program has its own command line for this
reset action.
52
lock
can
be
temporarily
PROGRAMMING LINE
Software version
Programming line
5
600
Preselection
(Mon-Sun / Mon-Fri / Sat – Sun / Mon...Sun)
st
601
1
phase On
st
602
1
phase Off
nd
603
2
phase On
nd
604
2
phase Off
rd
605
3
phase On
rd
606
3
phase Off
Programming line
Default values
(No /Yes)
Permanent Suspension of Programming
First perform a temporary suspension, then cancel
"Programming lock" on line 27.
Direct adjustment... (28):
Automatic storage
Correction of the setpoint with the knob is adopted
without a particular confirmation (timeout) or by
pressing the OK key.
Storage with confirmation
Correction of the setpoint with the knob will be
adopted only after pressing the OK key.
Enter changeover times:
Changeover times can be adjusted in a combined
way, i.e., identical times for several days or distinct
times for certain days. Preselecting groups of days
(e.g., Mon...Fri and Sat...Sun) having the same
changeover
times
changeover program considerably shorter.
In this case, individual settings will be lost!