Split system single phase type
Controlled floor drying function
Line no.
HC1
HC2
850
1150
851
1151
856
1156
857
1157
This function is used in the controlled drying of floors.
It adjusts the flow temperature to a temperature
profile. Drying is performed by floor heating via the
heating circuit with a mixing valve or with a pump.
Floor curing function
Off:
The function is deactivated.
Heating operational (Fh):
The
first
part
of
automatically completed.
Heating "ready for occupancy" (Bh)
The second part of the temperature profile is handled
automatically..
Heating "ready for occupancy" / Heating
operational
The full temperature profile (1st and 2nd part) is
performed automatically.
Heat pump
flow temp
X : Starting day
Floor curing setpoint manually
The flow temperature setpoint for the "Manual"
controlled floor drying function can be adjusted
separately for each heating circuit.
Floor curing day current
Displays the current flow temperature setpoint for the
controlled floor drying function
Maintenance Document 1589-3
Programming line
Floor curing function
Floor curing setpoint manually
Floor curing day current
Floor curing day completed
the
temperature
profile
Fh
Manual
No temperature profile is performed, but the control is
performed according to the "manual controlled drying
setpoint". The function is automatically terminated
after 25 days
Important
The standards and directions of the building
o
contractor must be followed!
This function will not work properly unless the
o
is
installation has been adequately made (hydraulics,
electricity, settings). Otherwise, the floors to be dried
may be damaged!
The function may be prematurely interrupted
o
by setting it to Off.
The maximum flow temperature limitation
o
remains active.
Bh
Fh + Bh
Floor curing day completed
Displays the current day of the controlled floor drying
function
Important:
After a power outage, the installation resumes the
controlled drying function as it was when the outage
occurred.
Days