4.3.1 IMIC Diagnostic software and field monitoring
The IMIC diagnostic Software allows the Operator to dial into an installed system to request current operating
parameters. All parameters are displayed in a concise tabular form and warnings are marked up in "red". The status of
each machine in the field is marked in green or red. Defective machines or error warnings are obvious by the first view.
Each call one full set of parameter of each machine is stored in a database and allows further processing. Each machine
needs a license to get onto the network. For more than one machine an additional license is required.
4.3.2 IMIC Diagnostic software and machine history
The collected data from field monitoring is stored in a database and allows further data processing of an individual
machine or entire field installations. Conclusions of the cooler (or it's components) usage are possible. It is worth to
have a look into machine history data before a service is scheduled.
4.4

Product consumption monitoring

Next to the operating parameters it is possible to collect consumption data of products and total water. A Flow meter
device, which is connected to the skeletal tower and Python, is needed to gather this information. The flow meter device
recognizes the opening times of each dispense head and calculates the throughput based on the product ratio, provided
that product, product ratio and flow rates have been preset correctly during installation. Required values are listed on
the installation protocol of the dispense tower. These values need to be adjusted when a product line or one of its
components has changed.
5.

Installation Requirements

5.1

Installation Sites

Comply with the valid national regulations for installation sites and electrical connections. Ventilation of the installation
sites must be appropriate for device output. Inadequate ventilation of the device will result in its overheating and being
destroyed. Always make certain that no intake or discharge vents are covered.
5.2

Electrical Connections

A socket outlet with an earthed contact featuring a maximum protection of 16 amperes is required.
The line voltage must always be within following tolerances: 230 VAC +6%/-10% / 50 Hz
6.

Installation

The device must be installed by a trained service technician. Please take care, that the socket for the unit is always
accessible.
There are no user serviceable items inside the equipment.
If the power supply cable to the unit is damaged, it has to be replaced by the manufacturer, the service partner or any
other qualified person to avoid safety hazard.
The unit must be planar aligned. Max angle of +/- 2° is permitted.
6.1

Water Connection

Connecting only to drinkable water!
Connect the device to a feed line with an inner diameter of 10 mm. We recommend using a water filter and a water
pressure regulator for the water input. To permit flushing of the filter, a t-piece should be mounted downstream of the
water pressure regulator. The water flow pressure must be minimum 2 bar (mount control pressure gauge on water
pressure regulator).