5.3
Servomotor adjustment (SQM 10)
1 - 4
: Limit switch cam (max. air damper opening)
2
: Limit switch cam (air damper closed)
3 - 5
: Minimum delivery (and ignition) position cam
6
: Positioning reading indicator
7
: Servomotor release
The servomotor contemporarily regulates, by transmission, air delivery
and pressure and delivery of the fuel being used.
It is fitted with a number of adjustable cams that action the same num-
ber of selector switches.
Cam pos.1:
limits maximum opening of the servomotor.
Cam pos.2:
limits servomotor limit switch in the 0° position.
When the burner is off, the air damper is completely
closed.
Cam pos.3:
fixes the minimum modulation position.
It is set in the factory at approx. 20° (just one type of fuel).
Cam pos.4:
limits maximum opening of the servomotor (for mixed burners working with gas).
Cam pos.5:
limits minimum delivery. It is set in the factory at approx. 20° (for mixed burners working with gas).
Cam rest:
available.
Important: the position of 130° must not be exceeded for limit switches (cam 1 - 4).