Quincy QGS 10 Instruction Book page 78

Oil-injected rotary screw compressors
Table of Contents

Advertisement

Adjusting the tension of the drive belts
Step
1
2
3
4
5
6
7
76
Tensioning of the belts must be performed with specific dedicated tooling.
Action
Stop the compressor, close the air outlet valve and switch off the voltage.
Remove the front door, the internal panel, the top cover and the pulley protection.
Loosen the 4 bolts (2) by one turn.
Adjust the belt tension by turning tensioning nut (1).
The force and deflection varies with the power of the unit, and with the total running
hours of the belt.
The values to be measured are indicated with a label (1) on the frame:
Retighten bolts (2).
Refit the bodywork panels.
Instruction book
2920 7113 41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qgs 15Qgs 20s