• Scroll Up or Down buttons (4-8) until <PrSL> is shown and then press Enter button (7).
• Pressure band 1 (<SEL.1>) is shown. Scroll Up or Down buttons (4–8) to pressure band 2
(<SEL.2>).
• Press Enter button (7) on the desired pressure band.

3.17 Calling up/modifying pressure band settings

Starting from the Main screen:
• Press Enter button (7) for 3 seconds to enter the Main menu.
• Select <ProG> and press Enter button (7) to enter the Programming menu.
• Scroll Up or Down buttons (4-8) to <reG.P> for regulation pressure.
• Press Enter button (7) to enter the submenu.
<LPr.1> is the parameter of Load Pressure band 1
<uPr.1> is the parameter of Unload Pressure band 1
<LPr.2> is the parameter of Load Pressure band 2
<uPr.2> is the parameter of Unload Pressure band 2
• Scroll Up or Down buttons (4-8) and press Enter button (7) to select parameter.
• The actual pressure used is shown. Scroll Up or Down buttons (4-8) to set pressure value
and press Enter button (7) to confirm. The unit blinks and the new setting is saved.

3.18 Calling up/modifying the unit of temperature

The unit of temperature measurement can only be changed when the compressor is stopped.
Starting from the Main screen:
• Press Enter button (7) for 3 seconds to enter the Main menu.
• Select <ProG> and press Enter button (7) to enter the Programming menu.
• Scroll Up or Down buttons (4-8) to <diSp> for display settings.
• Press Enter button (7) to enter the submenu.
• Scroll Up or Down buttons (4-8) to <tEMP> and press Enter button (7).
• The actual unit used is shown. Possible settings are <˚C > and <˚F >.
• Scroll Up or Down buttons (4-8) to set the unit of temperature and press Enter button (7) to
confirm. The unit blinks and is saved.

3.19 Calling up/modifying the unit of pressure

The unit of pressure measurement can only be changed when the compressor is stopped.
2920 7113 41