Step
1
Start-up
Step
1
2
2920 7113 41
Action
Check the oil level.
The oil level sight-glass (SG) should be between 1/4 and 3/4 full.
Start-up sheet
Action
Affix sheet (5) explaining the procedure for checking the motor rotation direction to the
cooling air outlet of the compressor (consult
Switch on the voltage. Press the start button for at least 3 seconds.
Check the rotation direction of the motor using sheet (5). If the motor rotation direction is
correct, the sheet on the top grating will be blown upwards. If the sheet remains in
place, the rotation direction is incorrect (see the pictographs on the label).
If the rotation direction is incorrect, switch off the voltage, open the isolating switch and
reverse two incoming electric lines.
Start and run the compressor for a few minutes. Check that the compressor is operating
normally.
Dimension
drawings).