Quincy QGS 10 Instruction Book page 65

Oil-injected rotary screw compressors
Table of Contents

Advertisement

Instruction book
Display
2920 7113 41
Flashing error code
Error
Possible
description
cause
Fan control
Fan control
probe failed.
probe
defective.
Dewpoint
Dewpoint
temperature
temperature
probe failed.
probe
defective.
High dewpoint.
Flow rate or
Call for service.
inlet
temperature
exceeding the
limit.
Refrigerant
leak.
Low dewpoint.
Hot gas bypass
Call for service
valve out of
order
Ambient
temperature
lower than the
limit
EPROM error
EPROM
defective
Maintenance
Maintenance is
required
overdue.
(Warning
appears after
6000 h)
Operations
Replace the
probe.
Replace the
probe.
Check flow rate
or inlet
temperature.
Check
refrigerant
charge.
Inspect hot gas
bypass valve.
Replace if
necessary.
Check ambient
temperature.
Dryer will stop
running.
Reset by
pressing one of
the four
buttons.
Replace
controller to
ensure dryer
reliability.
Dryer needs
maintenance.
Error can be
reset. See
section Reset
the
maintenance
due warning.
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qgs 15Qgs 20s

Table of Contents