Belt Set Exchange And Tensioning - Quincy QGS 10 Instruction Book

Oil-injected rotary screw compressors
Table of Contents

Advertisement

Instruction book
7.4

Belt set exchange and tensioning

Checking the belt tension
Step
1
2
3
4
2920 7113 41
Read the warning in the
Action
Stop the compressor, close the air outlet valve and switch off the voltage.
Remove the front door and the internal panel.
The force and deflection varies with the power of the unit, and with the total running
hours of the belt.
The values to be measured are indicated with a label (1) on the frame:
Refit the bodywork panels.
Preventive maintenance schedule
section.