Instruction book
Factory standard connection is 230 V and can be changed to 208 V or 460 V.
Terminal bridges (1) can be removed using a pair of pliers.
Additional terminal bridges are provided with the compressor.
Voltage stickers:
Locate the yellow voltage labels provided with the compressor.
Replace the existing label with the appropriate voltage label (208 V, 230 V or 460 V).
4.4
Pictographs
Ref.
1
2
3
4
5
6
7
9
10
11
2920 7113 41
Description
Working pressure
Hour meter
Dew point temperature
Start
Stop
Warning: voltage
Lightly oil gasket of oil filter, screw filter on and tighten by hand
Warning: switch off voltage and depressurise compressor before carrying out
maintenance work
Warning: hot parts
With all bodywork panels in place, push the start button.
• If the sheet is pulled downwards:
• Stop the compressor immediately and switch off the voltage.
• Reverse two incoming electric lines and repeat the previous step.
• If the sheet is blown away, the motor rotation direction is correct.
51