Page 1
Series ™ Direct Drive Rotary Screw Air Compressors Instruction Manual This manual contains important safety information and should be made available to all personnel who operate and/or maintain this product. Carefully read this manual before attempting to operate or perform maintenance on this equipment. Manual No.
Standard Warranty............................... 1 Safety Precautions and Warnings ........................2-4 Section II - Description General Description of Quincy QSF Series Air Compressors................5 The Compression Cycle............................6 Description of Air Flow ............................6 Description of Fluid Flow and Compressor Cooling System ................6-7 Modulation Control Standard..........................
NOTICE! This warranty is the sole warranty of seller. Any other warranties, expressed or implied, including any warranties of merchantability or fitness for a particular use are hereby excluded. Quincy Compressor – QSF Series...
Follow all maintenance procedures and check all safety devices on schedule. Never disconnect or tamper with the high air temperature (HAT) sensors. Compressed air is dangerous, do not play with it. Use the correct fluid at all times. Quincy Compressor – QSF Series...
Page 7
SPARE PARTS ORDERING -- Quincy Compressor maintains replacement parts for Quincy compressors. A parts manual is shipped with all new machines. Order parts from your Authorized Quincy distributor. Use only genuine Quincy replacement parts. Failure to use genuine Quincy parts may void your warranty.
Page 8
Hazards or unsafe practices that will result in death or serious injury. ! WARNING ! Immediate hazards which could result in death or serious injury. ! CAUTION ! Hazards or unsafe practices which may result in minor injury or product or property damage. Quincy Compressor – QSF Series...
Section II – Description General Description of Quincy QSF Series Air Compressors The compressor is a single stage, positive displacement, fluid-flooded helical screw type unit. The compressor consists of two precision-machined rotors. The male rotor is driven by a gear train, connected to motor shaft through a flexible drop out type coupling.
QSF specifications. The cooler fins must be kept clean at all times. Fluid leaving the receiver passes through a thermal mixing valve before traveling on to the cooler. The purpose of the thermal valve is to maintain a minimum fluid discharge temperature at the compressor of approximately 180 Fahrenheit. Quincy Compressor – QSF Series...
Auto/Dual Standard The Auto/Dual system is standard on the Quincy QSF Compressor. The control uses a programmable timer to shut the compressor down if it stays unloaded for the programmed time period. The timer should be set during unit start up for a minimum of six (6) minutes.
F. They are not suitable for salt laden, corrosive, dirty, wet or explosive environments. The QSF series compressors utilize 460V incoming power through a magnetic motor starter. A transformer in the control panel reduces this voltage to 120 VAC for the various controls on the unit, which is then reduced to 24 volt for the electronic controls.
This indicator signals when the filter element needs to be cleaned or replaced on the QSF. NOTE: Both the standard and stock versions include a programmable change interval timer on the air filter, fluid filter and the air/fluid separator element. Quincy Compressor – QSF Series...
High temperature shutdown may result. All models are intended for indoor installation; however, it is possible, with certain modifications, to accommodate some outdoor locations. Cabinet models are water-resistant but not water tight. Sheltering from rain, snow and freezing temperatures is mandatory. Quincy Compressor – QSF Series...
Page 15
The Quincy QSF models are essentially vibration free; however, some customers may choose to bolt the unit to the floor to prevent the accidental breakage of piping or electrical connections as a result of being bumped.
See control panel for the proper wiring diagram. Quincy would like to emphasize the importance of providing adequate grounding for air compressors. The common practice of grounding units to building structure steel may not actually provide adequate grounding protection, as paint and corrosion build-up may exist.
PSI maximum. Water temperature should be 50°F minimum/90°F maximum. Clean air is essential for your Quincy QSF compressor. Always select a source providing the cleanest air possible. When an outside air source is used, keep all piping as short and direct as possible. Use vibration isolators and support all piping correctly.
Operating more than one second in reverse rotation may cause damage to the airend. Fan Rotation (Air-cooled only) After checking the compressor rotation, also check the fan rotation. Fan airflow should be outward, that is, pushing the air through the coolers. Quincy Compressor – QSF Series...
Adjust the water temperature regulating valve to maintain 180 F discharge air temperature (water- cooled units only). • Observe compressor operation closely for the first hour of operation and frequently for the next seven hours. Stop and correct any noted problems. Quincy Compressor – QSF Series...
LED indicates a service timeout, along with a message blinking on the display. The controller is programmed with recommended service intervals on the FLUID FILTER and the AIR filter. These filters should be checked and serviced when convenient. Quincy Compressor – QSF Series...
Page 22
This also indicates that the compressor is about to start, when the auto-restart option is enabled. LOAD/UNLOAD: The left-most digit on the numeric display will show 'L' when the compressor is loaded, and 'U' when unloaded. Quincy Compressor – QSF Series...
Page 23
' FLu'. On servicing the Fluid filter or taking a sample, this counter should be re-set to the desired service interval. The LED's described above, will blink on the service intervals reaching '00'. As before, the setting is 'taken' when the display reading is steady. Quincy Compressor – QSF Series...
Page 24
8) Fluid timer expired: Fifth LED is steady, and message 'FLUI' flashes on the display. 9) Motor Overload: Sixth LED flashes fast. 10) Power line glitches ( loss of cycles > 40ms ), left 3 bars in the display flash, possible problems in the 3 phase power supply. Quincy Compressor – QSF Series...
Page 25
Remove tag and lock out tools. Restore power to unit. If electronic control was replaced, refer to the Program Setup Menu to program the replacement electronic control. Once completed, perform an operational test to assure unit is operating correctly. Quincy Compressor – QSF Series...
Safety solvents are available and should be used in accordance with their instructions. ! CAUTION ! Unusual noise or vibration indicates a problem. Do not operate the compressor until the source has been identified and corrected. Quincy Compressor – QSF Series...
Fluid Specifications We recommend that all Quincy gear drive rotary screw compressors be filled with QuinSyn IV or QuinSyn synthetic fluid. QuinSyn IV or QuinSyn is available from any authorized Quincy distributor. For applications requiring a food grade fluid, we recommend QuinSyn F. Sustained (3 hours or more) of discharge temperatures over 210 F, require the use of QuinSyn HP fluid.
FLUID TYPE - This should always be QuinSyn IV or QuinSyn F fluids. g) SERIAL NUMBER - The unit serial number of the Quincy compressor the fluid sample was taken from. h) MODEL NUMBER - The model number of the Quincy compressor that the fluid sample was taken from.
The fluid filter is a spin on, full flow unit. Replacement of the filter requires spinning off the complete cartridge and replacing it with a new one. USE GENUINE QUINCY REPLACEMENT FILTERS ONLY. The initial filter change should occur after the first 500 hours of operation. During normal service, the filter cartridge should be replaced under the following conditions, whichever occurs first: •...
20 ohms. 8) If the separator element has a gasket on each side of the flange, repeat steps 3 through 7. 9) If the separator element fails any of the above tests, return it to your Quincy Distributor for replacement.
Turn nuts down until they’re touching the compression plate. Do not over compress o-ring. Tighten nuts by turning clockwise ½ turn in a cross pattern. Over tightening the compression plate will deform the separator, reducing performance. SEPARATOR RETAINING PLATE & THREADED ROD NYLOK NUT QGV-200 Separator Installation Quincy Compressor – QSF Series...
When excessive fluid carryover is detected. • Every fluid change. • Once per year. Scavenge Line Sight Glass NOTE: Do not ream the orifice or change the orifice size. Do not install the orifice reversed. Quincy Compressor – QSF Series...
Warranty will be void if a failure is determined to be caused by inadequate filtration. Control Line Air Filter An automatic draining control line filter is used. Draining occurs only when the compressor is in the unloaded condition. Quincy Compressor – QSF Series...
Should you decide to replace the seal yourself, be certain to ask your Quincy distributor for the complete illustrated instructions (available as a Service Alert) at the time you order the seal and special tools.
6. Apply a thin film of compressor fluid to the O-ring and seal lip of the outer fluid slinger. Install the outer slinger over the end of the rotor shaft and push into the scavenge bore using both thumbs. 7. Reinstall drives motor and coupling. Reinstall the coupling guards before starting the compressor. Quincy Compressor – QSF Series...
Serious personal injury and property damage may result. ! WARNING ! Failure to install flareless tubing or fittings correctly may result in the tubing coming apart under pressure. Serious injury and property damage may result. Quincy Compressor – QSF Series...
To decrease fluid temperature, increase water flow by turning the adjustment screw counter clockwise. Water pressure should be 40-PSI minimum/100 PSI maximum. Water temperature should be 50°F minimum/90°F maximum. Quincy Compressor – QSF Series...
FAILURES ON HEAT EXCHANGERS CAUSED BY PLUGGING OR CORROSION ARE NOT COVERED UNDER WARRANTY. Fluid Piping Fluid piping on QSF units incorporates a machine-rolled flare tube and a "SEAL-LOK" fitting. Proper assembly methods for "SEAL-LOK" fittings are listed below. Quincy Compressor – QSF Series...
Inlet valve not fully open Correct in accordance with the instructions in “Inlet valve not opening or closing in relation to air demand” section of troubleshooting guide. Plugged air intake filter Replace air filter element. Quincy Compressor – QSF Series...
Page 44
Correct in accordance with the instruction in “Fluid Breakdown” section of the troubleshooting guide. Incorrect fluid separator element Use genuine Quincy replacement elements only. Extreme operating conditions such Operate compressor at recommended reservoir pressure and air as high compressor discharge discharge temperature.
Page 45
Replace fluid filter element. Clogged fluid cooler Check fluid cooler for varnishing and rust deposits. If condition exist, clean cooler thoroughly and contact Quincy service technician for instructions. Excessive ambient temperatures Maximum ambient for proper operation is listed in data sheet.
Page 46
Compressor operating in highly Use remote air intake mounting contaminated atmosphere Air cleaner not adequate for Use specialized air filter. Contact an Authorized Quincy Distributor. conditions Inlet valve not opening or closing in relation to air demand Improper setting of operating...
Page 47
Excessive Water in Plant Air Distribution System Incorrect operating temperatures Check thermal valve. Discharge temperature should be a minimum of 170°F. Clogged moisture separator/trap Clean or replace as required. Installation/Application Check other compressors on same system. Faulty cooler-leaks Replace cooler. Quincy Compressor – QSF Series...
Page 48
Faulty receiver pressure gauge Check gauge for accuracy and replace if necessary. Adjust control settings. Faulty pressure relief valve Check pressure relief valve for correct pressure setting. If valve is still leaking, replace with new relief valve. Quincy Compressor – QSF Series...
Change fluid and fluid filter/ sooner if indicated by lubricant sample analysis. Periodically/yearly Go over unit and check all bolts for tightness. Change air/fluid separator. Change air filter. Lubricate motors. Check safety shutdown system. Contact a qualified serviceman. Test pressure relief valve for proper operation. Quincy Compressor – QSF Series...
Performance information should be noted and recorded on newly installed units so that any reduction in effectiveness can be detected. Any loss in efficiency can normally be traced to an accumulation of oil sludge, or water scale. Added 09/2010 Quincy Compressor – QSF Series...
Page 51
Upon completion of cleaning, be certain that all chemicals are removed from the shell side and the tube side before the heat exchanger is placed into service. Added 09/2010 Quincy Compressor – QSF Series...
Page 52
QUINCY COMPRESSOR AND ORTMAN FLUID POWER DIVISIONS STANDARD TERMS AND CONDITIONS LEGAL EFFECT: Except as expressly otherwise agreed to in writing by an authorized representative of Seller, the following terms and conditions shall apply to and form a part of this order and any additional and/or different terms of Buyer’s purchase order or other form of acceptance are rejected in advance and shall not become a part of this order.
Page 53
ENVIROMENTAL AND OSHA REQUIREMENTS: At the time of shipment of the equipment from the factory, Quincy Compressor / Ortman Fluid Power will comply with the various Federal, State and local laws and regulations concerning occupational health and safety and pollution.