Taking Out Of Operation - Quincy QGS 10 Instruction Book

Oil-injected rotary screw compressors
Table of Contents

Advertisement

Instruction book
Step
1
2
3
5.4

Taking out of operation

2920 7113 41
Action
Push the start/stop button (6) on the controller. The compressor will unload. When the
unload time has elapsed, the compressor is stopped and the controller goes back to the
main screen.
To stop the compressor immediately in the event of an emergency, press button (S3).
See section
Control
panel. After remedying the fault, unlock the button by pulling it out.
Only use emergency stop button in the event of an emergency. Avoid using the button
for normal stopping of the compressor.
Close air outlet valve and switch off the voltage to the compressor.
Open condensate drain valve (4) of the air receiver for a few seconds to drain any
condensate and then close the valve.
The air dryer and the air receiver remain under pressure.
The integrated filter (if installed) remains pressurised.
If maintenance or repair work is necessary, consult the
relevant safety precautions.
Condensate drain valve on air receiver
Problem solving
section for all
59