Maintenance; Preventive Maintenance Schedule - Quincy QGS 10 Instruction Book

Oil-injected rotary screw compressors
Table of Contents

Advertisement

Instruction book
6

Maintenance

6.1

Preventive maintenance schedule

Warning
Warranty-Product Liability
Use only authorized parts. Any damage or malfunction caused by the use of unauthorized parts
is not covered by Warranty or Product Liability.
General
When servicing, replace all removed gaskets, O-rings and washers.
Intervals
Carry out maintenance at the interval which comes first. The local Customer Center may overrule
the maintenance schedule, especially the service intervals, depending on the environmental and
working conditions of the compressor.
The "longer interval" checks must also include the "shorter interval" checks.
Preventive maintenance schedule
Period (1)
Daily
3–monthly
"
"
"
Yearly
"
"
"
"
2920 7113 41
Before carrying out any maintenance, repair work or adjustments, proceed as
follows:
• Stop the compressor.
• Switch off the voltage and open the isolating switch.
• Close the air outlet valve and open the manual condensate drain valves.
• Depressurize the compressor.
For detailed instructions, see the next sections.
The operator must apply all relevant
Running hours
Action
(1)
--
Check the oil level.
After stopping, drain the condensate from the air receiver by means
of the manual drain valve (4), see section Stopping.
500 (2)
Inspect the air filter. Clean if necessary.
2000
Check the tension and the condition of the belts. Adjust if necessary.
1000 (2)
Inspect the oil cooler. Clean if necessary.
"
For versions with dryer: inspect the condenser of the dryer. Clean if
necessary.
2000
Replace the oil filter.
"
Replace the air filter.
4000 (2)
Replace the oil separator element.
4000
Replace the belts.
"
Install the drain wear kit.
Safety