Commissioning
Fuse table
Heat pump
400V, 3N~
16 A
5 - 17 kW
400V, 3N~
10 A
3 - 12 kW
Positioning of the outdoor sensor
Danfoss Heating Solutions
DHP-H Varius Pro+/DHP-L Varius Pro+
Heat pump + Immersion Heater
3 kW
6 kW
20 A
25 A
16 A
20 A
Recommended location
Unsuitable location
▪ Position the outdoor sensor on the north or north west side of the
house.
▪ Make sure that the outdoor sensor is not placed in direct sun light.
▪ For taller buildings, the sensor should be positioned between the
second and third floors.
▪ The sensor location must not be completely protected from the
wind but not placed in a direct draft.
▪ The outdoor sensor must not be placed on reflective panel walls.
▪ The sensor must be positioned at least 1 m from openings in the
walls which may emit hot air.
▪ If the sensor cable is connected through a pipe, the pipe must be
sealed so that the sensor is not affected by outgoing air.
Immersion Heater only
9 kW
3 kW
32 A
6 A
25 A
6 A
VIJSG202
6 kW
9 kW
10 A
16 A
10 A
16 A