Heating Settings; Default Heating Settings - Danfoss DHP-H Varius Pro+ Manual

Hide thumbs Also See for DHP-H Varius Pro+:
Table of Contents

Advertisement

Commissioning
5.7

Heating Settings

In Heating settings, you can set seasonal stop, min/max supply line temperature and comfort factor.
The Comfort factor (0 - 3) influences the desired Supply line (HP) value. If the Comfort factor is set to for example 3, an increase of the of
the Comfort wheel setting with +1 will result in an increase of the supply line temperature with +3 ºC.
Caution
If your house has under floor heating and heat sensitive floors, the supply line temperature must not exceed certain temperatures. Oth-
erwise the floor might get damaged.
5.8

Default Heating Settings

The control system has two different default settings available from factory:
▪ radiator system (factory default)
▪ underfloor heating
The default settings will affect the heat curve settings and minimum and maximum supply line temperature. Further adjustments may
be necessary also after setting default settings.
Important: If the system shall be configured to Underfloor heating or similar, it is a must to set the heat pumps default value to floor
heating. If this is not done, the "factory reset" button will reset the heat curve and max/min supply line temperatures to default values
for radiator systems, which may cause damages on systems with e.g. floor heating.
To change default heat settings from Radiator to Floor heating (or reverse):
18
DHP-H Varius Pro+/DHP-L Varius Pro+
1. Press
2. Press
3. Press
4. Make the desired changes.
5. Confirm settings by pressing
Adjusting the minimum and maximum supply temperatures is particu-
larly important if your home has under floor heating.
1. Press
2. Press
3. Press
4. Press
5. Make the desired changes.
6. Press
7. Confirm settings by pressing
VIJSG202
on the Start screen to open the Menu screen.
if the Heat settings window is not shown.
on the Start screen to open the Menu screen.
if the Heat curve window is not shown.
for underfloor heating systems or
to set the new "factory reset" value to the selected system.
for radiator systems
Danfoss Heating Solutions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dhp-l varius pro+

Table of Contents