Vent Configurations For 54 Pb Only For 42 Pb; Minimum Vent Configuration - FireplaceXtrordinair ProBuilder 42 Linear Instruction Manual

Table of Contents

Advertisement

32
Vent Configurations for 54 PB ONLY

Minimum Vent Configuration

 Use 5x8" Diameter Coaxial Vent
 NOTE: Use the included thimble assembly whenever passing through a wall (use on front
and back of wall penetration). See picture below.
 The termination must fall within the shaded area shown in the chart. Use the indicated
restrictor positions.
 One 45° elbow may be used on the horizontal run.
 HINT: Use minimum vent kit "H" (96200332) from Travis Industries (additional vent may be
required).
PB 54 Linear Only
5 feet (1.5 m)
0 feet
Use the included wall thimble when
penetrating a wall. Part #96200101
© Travis Industries
Installation
(for qualified installers only)
Exhaust Restrictor # 1 (stock)
Diffuser Closed (stock)
8" Vent
1' Vertical Section Attached Directly to Fireplace
For 42 PB see page 29
Max. 4' Horizontal Section(s)
Min. 3.9" Horizontal Section
6/3/19 - 1453
PB 42 & 54 MV/GSB2 Install

Advertisement

Table of Contents
loading

This manual is also suitable for:

Probuilder 54 linear

Table of Contents