Vent Configurations for 42 PB ONLY

Minimum Vent Configuration

 Use 5x8" Diameter Coaxial Vent
 NOTE: Use the included thimble assembly whenever passing through a wall. (use on front
and back of wall penetration). See picture below.
 The termination must fall within the shaded area shown in the chart. Use the indicated
restrictor positions.
 One 45° elbow may be used on the horizontal run.
 HINT: Use minimum vent kit "H" (96200332) from Travis Industries (additional vent may be
required).
PB 42 Linear Only
Elbow Placed Directly on Top of Fireplace
3 feet (0.915m)
0 feet
Use the included wall thimble when
penetrating a wall. Part #96200101
© Travis Industries
Installation
(for qualified installers only)
Exhaust Restrictor # 1 (stock)
Diffuser Closed (stock)
For 54 PB see page 32
Max. 20' (6M) Horizontal Section(s)
6/3/19 - 1453