7500-Rev2.5 Greensand Filter Installation & Startup Guide
14. IMPORTANT: you must program the time and then start a backwash and rinse. The filter system
must be backwashed and rinsed several times before using. See following pages for instructions.

Pot Perm Tank Set Up

1. First remove the rubber band in the pot perm tank,
that comes on the float assembly from the
manufacturer.
2. Add enough clean water to the pot perm solution tank
to bring water level about 1" above the felt pad.
3. Add one 2‐lb or one 5‐lb jug of potassium
permanganate granules to the potassium perm tank
by pouring it directly on top of the white felt pad.
4. Do not pour permanganate down the white plastic
brine well where the black line is attached.
See the over‐flow barbed fitting for the safety float on
5.
the side of the perm tank.
You do not have to connect this to a drain. But, if the
6.
safety float were to malfunction, there is a small
chance that pot perm solution will leak or drip out of
this fitting.
If this would cause a big mess where you have
7.
installed the greensand filter, hook some tubing to
this and run to a bucket, floor pan or floor drain. Normally no pot perm solution will leak out
of this fitting
.