Service Mode; Sensor Test Mode & Panel Switch Test Mode - GRAPHTEC FC8000-60 Service Manual

Cutting plotter
Table of Contents

Advertisement

8.5 Service mode

8.5.1 Sensor Test Mode & Panel Switch Test Mode
This mode checks the sensor status and the control panel switch status. If there is a bad sensor you will
observe one of the symptoms in the table below.
Please check the relevant sensor(s).
Sensor
Y home sensor
The pen block hits the right side plate.
Cam sensor
The plotter displays "LOAD MEDIA!" when media is already loaded.
Pinch roller sensor
The pen block hits the left side plate.
+X, -X media sensor Media drops out of the plotter.
How to test the sensors
(1) Load an A2 or larger size sheet of paper in the plotter.
(2) Enter the adjustment menu (see Section 7.3.4).
(3) Press the MENU key to display the menu shown below.
(5) Press the F1 key to display the menu shown below.
Each short forms are corresponding to the sensors and the control panel switches as shown below.
Short form
Sensor or key
UP
Up arrow key
YHME
Y home sensor
XFRONT Front media sensor XREAR
STOP
STOP key
CCUT
Cross Cut key FAST
COND
Condition key ENTR
F4
4 key
(6) Cover the front media sensor with a piece of paper.
The status of XFRONT changes from "L" to "H".
(7) Cover the rear media sensor with a piece of paper.
The status of XREAR changes from "L" to "H".
(8) Move the pen block to the far right. When the pen block reaches the home position flag, the status of
YHME changes from "L" to "H".
(9) Lower the media set lever to raise the pinch rollers. The status of CAM changes from "L" to "H".
(10) Move the pen block to the left and right. When the pen block crosses the pinch roller, the status of PROL
changes from "L" to "H".
FC8000-UM-251-9370
Short form
Sensor or key
DN
Down arrow key
PROL
Pinch roller sensor CAM
Rear media sensor
MENU
Menu key
Fast key
Enter key
F3
3 key
Symptom
Short form
Sensor or key
LT
Left arrow key
Cam sensor
COPY
Copy key
ORIG
Origin key
F2
2 key
8-16
8. TROUBLESHOOTING
Short form
Sensor or key
RT
Right arrow key
F1
1 key

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fc8000-75Fc8000-100Fc8000-130Fc8000-160

Table of Contents