7. ADJUSTMENT
7.3.14 Adjusting the Pen Exchange Y Direction Value (2-pen model)
This adjustment will set the pen exchange Y direction value.
This value is used for the 2nd pen pen exchange.
If you replace the main board, use the following procedure to input the recorded adjustment values.
(1) Confirm that the DIP switch 7 of SW1 is OFF. (2-pen model mode)
(2) Enter the adjustment menu (see Section 7.3.4).
(3) Press the Up or the Down position key until the menu shown below is displayed.
(4) Press the F3 key to display the menu shown below.
(5) Press the F2 key to move the pen carriage to the exchange position.
This gap should be 1.1 mm.
(6) Press the F3 key to display the following menu to adjust the gap.
(7) Adjust gap using the up or the down position key.
(8) Measure the gap between the 2nd pen holder and the 2nd pen station.