Modbus RTU/ASCII Master
Protocol
Modbus RTU Slave
Protocol
Modbus TCP/IP
Protocol
Remote I/O
Fbus
Ebus
Send Email
SMS:
Short Message Service
Redundancy Solution
CAN/CANopen
Optional I/O Functions
PWM Output
Pulse Width Modulation
Output
Counters
Parallel DI Counter
Remote DI Counter
Remote High Speed
Counter
*Note:
COM3 ~ COM8 are resided at the optional
Getting Started: PAC-5007/5107/5207/5307 Ver. 1.1, 12/2011
8
Max. 2 COM Ports: COM1, COM2 and COM3 (*).
(To connect to other Modbus Slave devices)
Max. Modbus_xxx Function Block amount for 2 ports: 128.
Max. 2 COM Ports, COM1 and one of (COM2, COM3) (*).
For connecting ISaGRAF, PC/HMI/OPC Server & MMI panels.
Max. 6 connections, Ethernet ports support Modbus TCP/IP Slave Protocol
for connecting ISaGRAF & PC/HMI.
One of COM2 or COM3 (RS-485)
or RU-87Pn + I-87K High Profile I/O boards) as Remote I/O. Max. 64 I/O
modules for one PAC.
Built-in COM2 Port to exchange data between ICP DAS's ISaGRAF PACs.
To exchange data between ICP DAS's ISaGRAF Ethernet PACs via Ethernet
port.
Actively or passively sending E-mail via Ethernet port through internet.
Max.10 receivers for each sending and can send E-mail with an attached file.
(Max. file size is about 488 KB)
One of COM1 or COM3 (RS-232)
SMS. User can request data/control the controller by cellular phone. The
controller can also send data & alarms to user's cellular phone. Optional
GSM modem: GTM-201-RS232 (GSM/GPRS 850/900/1800/1900)
Note: μPAC-5207, 5307 has built-in GPRS, no external GSM/GPRS modem
required.
Two PACs plug with XW107 in slot0. One is Master, one is Slave. Master
handles all inputs & outputs at run time. If Master is damaged (or power off),
Slave will take over the control of Bus7000b. If Master is alive from damaged
(or power up again), it takes the control of Bus7000b again. The change over
time is about 5 seconds. Control data is exchanging via Ebus (if using a cross
cable, no require any Ethernet Switch). All I/O should be RS-485 I/O except
the status I/O in the slot 0: XW107.
Use COM1 or COM3 ~ COM8
converter) to support CAN/CANopen devices and sensors. One PAC supports
max. 3 RS-232 ports to connect max. 3 I-7530 modules. Please refer to:
www.icpdas.com > FAQ > Software > ISaGRAF Ver.3 (English)
All
XW-board series
support PWM output. Max. 8 channels for one controller.
500 Hz max. for Off = 1 & On = 1 ms
Output square wave: Off: 1 ~ 32767 ms, On: 1 ~ 32767 ms
All
XW-board series
support DI counter.
Max. 8 channels for one controller. Counter value: 32-bit
500 Hz max. Min. ON & OFF width must > 1 ms
All remote I-7000 & I-87K DI modules support counters. 100 Hz max.
value: 0 ~ 65535
Optional I-87082: 100 kHz max. ,32-bit
(*)
supports I-7000 I/O modules & (I-87Kn
(*)
can link to a GSM modem to support
(*)
to connect one I-7530 (RS-232 to CAN
XW-board series
if it is plugged inside the μPAC-5x07.
-
086