MPP Solar PIP8048MAX User Manual page 23

Solar inverter / charger
Hide thumbs Also See for PIP8048MAX:
Table of Contents

Advertisement

27
Floating charging voltage
AC output mode
*This setting is only
28
available when the inverter
is in standby mode (Switch
off).
Low DC cut-off voltage:
 If battery power is only
power source available,
inverter will shut down.
 If PV energy and
battery power are
available, inverter will
29
charge battery without
AC output.
 If PV energy, battery
power and utility are all
available, inverter will
transfer to line mode
and provide output
power to loads.
default: 54.0V
If self-defined is selected in program 5, this program can be set
up. Setting range is from 48.0V to 62.0V. Increment of each click
is 0.1V.
Single: This inverter is used
in single phase application.
When the inverter is operated in 3-phase application, set up
inverter to be operated in specific phase.
L1 phase:
L3 phase:
default: 44.0V
If self-defined is selected in program 5, this program can be set
up. Setting range is from 42.0V to 48.0V. Increment of each click
is 0.1V. Low DC cut-off voltage will be fixed to setting value no
matter what percentage of load is connected.
21
Parallel: This inverter is operated
in parallel system.
L2 phase: