Recommended Panel Configuration
When selecting proper PV modules, please be sure to consider the following parameters:
1. Open circuit Voltage (Voc) of PV modules not to exceed maximum PV array open circuit voltage of the
inverter.
2. Open circuit Voltage (Voc) of PV modules should be higher than the start-up voltage.
INVERTER MODEL
Max. PV Array Power
Max. PV Array Open Circuit Voltage
PV Array MPPT Voltage Range
Start-up Voltage (Voc)
Recommended solar panel configuration:
Solar Panel Spec.
(reference)
Min in series: 4pcs, per input
- 250Wp
Max. in series: 12pcs, per input
- Vmp: 30.7Vdc
- Imp: 8.3A
- Voc: 37.7Vdc
- Isc: 8.4A
- Cells: 60
9pcs in series, 1 string 9pcs in series, 1 string
SOLAR INPUT 1
4pcs in series
x
12pcs in series
x
6pcs in series
6pcs in series, 2
strings
x
8pcs in series, 2
strings
x
10pcs in series, 1
string
12pcs in series, 1
string
6pcs in series, 2
strings
7pcs in series, 2
strings
8pcs in series, 2
strings
PIP8048MAX
90Vdc~450Vdc
SOLAR INPUT 2
Q'ty of panels Total Input Power
x
4pcs in series
x
12pcs in series
6pcs in series
x
6pcs in series, 2
strings
x
8pcs in series, 2
strings
10pcs in series, 1
string
12pcs in series, 1
string
6pcs in series, 2
strings
7pcs in series, 2
strings
8pcs in series, 2
strings
9
8000W
500Vdc
80Vdc
4pcs
1000W
4pcs
1000W
12pcs
3000W
12pcs
3000W
12pcs
3000W
3000W
12pcs
3000W
12pcs
16pcs
4000W
16pcs
4000W
18pcs
4500W
20pcs
5000W
24pcs
6000W
24pcs
6000W
28pcs
7000W
32pcs
8000W